radiology-deep-learning
Design/train/audit imaging DL pipelines, splits, tuning and validation; not deployment studies.
Install / Use
npx skills add huang-sir1/radiology-skills --skill radiology-deep-learningInstalls into whichever agent you are using.
SKILL.md
Installable skill definition
Quality Score
Category
AutomationSupported Platforms
Our assessment of radiology-deep-learning
radiology-deep-learning scores 82/100 on our quality scale, 2290th of 2,780 Automation skills we index.
Its SKILL.md is 9.7 KB long, well organised into 8 sections and no code examples: a thorough specification that gives an agent plenty to work with.
With 1,785 GitHub stars, it is one of the more widely adopted skills in the catalogue.
Maintenance, license and trust
- The repository was last updated about 2 months ago, so radiology-deep-learning is actively maintained.
- Our last check on 2026-11-07 found the source still online.
- No license is declared. By default that means all rights are reserved: you can read it, but reusing or redistributing it is not clearly permitted. Ask the author before building on it commercially.
- Its trust signals score 88/100, with 1 caution from licensing, adoption, age or documentation. These come from repository metadata, not a code audit — read the skill file before letting an agent act on it.
Safety scan
No issues foundOur scan of the whole file found no instruction hijacking, hidden characters, credential access, data exfiltration or destructive commands. An AI review of the same text found nothing harmful.
AI review by kimi-k2.7-code on 2026-10-01. Automated pattern scan on 2026-10-01. It catches known dangerous patterns, not every risk — read a skill before letting an agent act on it.
radiology-deep-learning compared with similar skills
All 4 of these similar skills score higher than radiology-deep-learning; compare them before choosing.
| Skill | Score | Stars | Updated | Format |
|---|---|---|---|---|
| radiology-deep-learning (this skill)by huang-sir1 | 82 | 1.8k | 56d ago | SKILL.md |
| taste-skillby Leonxlnx | 100 | 116.8k | 8d ago | CLAUDE.md |
| Agent-Reachby Panniantong | 100 | 112.3k | 8d ago | CLAUDE.md |
| rufloby ruvnet | 100 | 81.9k | today | CLAUDE.md |
| Claude-Code-Game-Studiosby Donchitos | 100 | 39.7k | 7d ago | CLAUDE.md |
Frequently asked questions
- How do I install radiology-deep-learning?
- Run
npx skills add huang-sir1/radiology-skills --skill radiology-deep-learning. The install tabs above show the steps for each supported agent. - Which AI agents does radiology-deep-learning work with?
- It is written for Universal, as a SKILL.md file. Other agents that read the same format can often use it too.
- Is radiology-deep-learning safe to use?
- Our scan of the whole file found no instruction hijacking, hidden characters, credential access, data exfiltration or destructive commands. An AI review of the same text found nothing harmful. It declares no license and scores 88/100 on trust signals. Skills are instructions an agent will follow, so read the file before installing it and do not approve commands you do not understand.
- Is radiology-deep-learning still maintained?
- The repository was last updated about 2 months ago, so radiology-deep-learning is actively maintained.
Skill content
View source on GitHubname: radiology-deep-learning description: "Design/train/audit imaging DL pipelines, splits, tuning and validation; not deployment studies."
Imaging Deep-Learning Study Design
Use this skill to design (or audit) an imaging deep-learning study so it is reproducible, honestly validated, and CLAIM-compliant. DL imaging papers get torn apart for slice-level splits, patient overlap, test-set tuning, no external validation, and baselines that are too weak to make "deep learning wins" mean anything. This skill encodes the architecture/training choices and the partition hygiene reviewers enforce.
Core stance
- Patient-level everything. Splits, augmentation, and any data-dependent step respect the patient boundary — slices/lesions/sequences/timepoints from one patient never span sets.
- Right capacity for the data. Small cohorts → transfer learning, self-supervised pretraining, strong simple baselines, heavy augmentation, and nested CV — not a giant model trained from scratch on 200 images.
- Beat a real baseline. "DL is better" needs a fair comparator: a radiomics/clinical model, a strong simpler network, or radiologists — tuned as carefully as the proposed model.
- Inputs declared. State exactly how images, masks, clinical variables, text, and molecular data enter the model (channels, crops, fusion point), and how missing modalities are handled.
- Validation must match the claim. Freeze the pipeline before evaluation. Internal patient-level resampling can support bounded development or feasibility claims; temporal, geographic, external, or deployment claims require a genuinely untouched population representing that transport step (→ radiology-design/validation-strategy).
- Report fit-for-purpose performance. Include uncertainty and failure cases. Use calibration for probabilistic predictions and decision-analytic utility only when a real decision and threshold range are defined (→ radiology-stats).
- Select trustworthiness analyses by risk and use. Interpretability, predictive uncertainty,
OOD/robustness and fairness analyses are required when they answer a named failure mode, support a
proposed use, or are part of a foundation/deployment evaluation; do not add them as ceremonial
high-impact-journal checkboxes (→
interpretability-uncertainty.md). - Integrity. Never invent performance, training curves, or hyperparameters; mark what must be run.
When to use
- "Design a CNN/Transformer/3D/segmentation/detection/prognostic imaging model." / "影像深度学习课题设计。"
- "Transfer learning vs self-supervised vs from scratch for my cohort size?"
- "How should images + clinical + pathology/text enter the model (multimodal fusion)?"
- "Augmentation, class imbalance, hyperparameter search, baselines — how to set up?"
- "Audit my DL Methods for slice-level leakage / patient overlap / test-set tuning."
When to open extra files
| File | Open when | |---|---| | references/architecture-choice.md | Choosing 2D/2.5D/3D CNN, Transformer/ViT, segmentation/detection/prognostic heads; foundation models; capacity vs cohort size | | references/training-protocol.md | Transfer/SSL/from-scratch, splits, augmentation, class imbalance, loss/optimizer/schedule, hyperparameter search, checkpointing, seeds | | references/multimodal-inputs.md | How images/masks/clinical/text/molecular inputs enter the model; fusion strategies; missing-modality handling | | references/dl-leakage-audit.md | The DL-specific leakage/validity checklist reviewers weaponise | | references/interpretability-uncertainty.md | Explainability (Grad-CAM/SHAP/attention) reported without overclaiming; uncertainty quantification (MC dropout, ensembles, conformal prediction); robustness/OOD testing; FUTURE-AI framing | | references/foundation-models-trustworthy-ai.md | Foundation models, ViT, SSL, VLM/report generation, 3D radiology models, adapter/LoRA, UQ/XAI/causal robustness, or deployment-grade trustworthy AI | | references/foundation-model-data-genealogy-and-privacy.md | Pretraining sources are reused, closed or uncertain; audit patient/derivative overlap, contamination wording, memorisation/privacy threats, provider retention or federated leakage | | references/experiment-and-model-card.md | Freezing experiment provenance, model/data cards, run manifests, negative results, test-set access, compute/environment, or a final reproducibility package |
Workflow
- Confirm the design (reuse
radiology-design) — task, endpoint, unit (patient-level), cohorts, validation type, realistic capacity given n. - Choose architecture (architecture-choice.md) — dimension, family, task head; justify capacity vs cohort size; pick the baseline(s) to beat.
- For foundation/trustworthy-AI designs, open
foundation-models-trustworthy-ai.mdand, when pretraining sources are reused, closed or uncertain,foundation-model-data-genealogy-and-privacy.md. Specify the overlap-evidence state, adaptation, baseline ladder, calibration, UQ, XAI stability, OOD/robustness, equity/fairness, privacy threat model, and shortcut/confounder audits. - Define inputs (multimodal-inputs.md) — channels/crops/fusion; missing-modality rule; leakage-safe use of masks and clinical/text/molecular data.
- Set training (training-protocol.md) — transfer/SSL/scratch, patient-level splits, augmentation, imbalance handling, loss/optimizer/schedule, nested-CV hyperparameter search, seeds, checkpoint selection (on validation, never test).
- Validate — use patient-level internal evaluation and add temporal/geographic/external evaluation when the intended claim requires that transport step; keep the pipeline frozen and report claim-relevant performance, uncertainty and failure cases (→ radiology-stats).
- Run justified trustworthiness analyses (interpretability-uncertainty.md) — name the failure mode or decision each XAI/UQ/OOD/robustness analysis addresses, choose a method matched to the architecture, and report bounded results rather than only flattering examples.
- Freeze experiment provenance (
experiment-and-model-card.md) — data/split manifest, configurations, seeds, compute/environment, checkpoint rule, test-access log, model card, failure/negative-result log, and deviations. - Audit leakage (dl-leakage-audit.md) and write Methods to CLAIM 2024.
Output contract
Model design— architecture, task head, capacity rationale, baseline(s).Input spec— how each modality enters; fusion point; missing-modality handling.Training protocol— pretraining strategy, splits, augmentation, imbalance, loss/optim/ schedule, hyperparameter search, seeds, checkpoint rule — reproducibly.Validation plan— internal evaluation plus any claim-required transport evaluation; fit-for-purpose metrics, uncertainty and failure cases.Interpretability & uncertainty— when justified, the named risk/use, method, parameters, quantitative check, and bounded claim it supports (→ interpretability-uncertainty.md).Trustworthiness modules— for foundation/VLM/deployment-grade models: calibration, UQ, OOD/fairness, XAI stability, shortcut/confounder audit, pretraining-overlap state and a use-specific privacy threat model; do not infer fairness from subgroup AUC alone.Leakage audit— pass/fail per item + fix.Experiment/model record— data/split/run manifests, model card, configuration and checkpoint provenance, environment/compute, negative results, and deviations actually available.Table handoff— baseline/ablation/performance/calibration/fairness value keys and configuration rows forradiology-table.Methods paragraph— CLAIM-aligned prose (+ 待确认 for Chinese authors).
Quality bar
A good DL design is reproducible from the protocol, splits at the patient level, beats a fair baseline, freezes the pipeline before claim-matched evaluation, and reports relevant uncertainty and failure cases — not a single AUC from a slice-level split.
Handoffs
- Series/phase/sequence qualification, acquisition/reconstruction, quantitative transforms,
artifacts, dose, phantom/test-retest and protocol drift →
radiology-acquisition-qc; consume its accepted-image gate and deviations before training/evaluation. - Hand-crafted feature comparison / deep-feature extraction context →
radiology-radiomics. - Segmentation/detection ground-truth mask SOP and reader reproducibility →
radiology-annotation. - CLAIM/TRIPOD+AI audit, FUTURE-AI/TRIPOD-LLM edge cases →
radiology-reporting. - Metrics, CIs, DeLong, calibration, MRMC, sample size →
radiology-stats. - Hyperparameter/configuration sensitivity, matched benchmark fairness, component ablation,
seed/run failure boundaries and efficiency evidence →
radiology-method-evaluation; this skill still owns model/training implementation. - Validation-type design (external/temporal/multi-center) →
radiology-design. - Biological interpretation of deep features →
radiology-radiogenomics. - Reader study / prospective deployment / monitoring for drift →
radiology-translation. - Figures (architecture, ROC, calibration, Grad-CAM, uncertainty plots) →
radiology-figure. - Tables (performance, ablation, subgroup/fairness, hyperparameters, failure cases) →
radiology-table. - Reframing this as a funding proposal instead of / alongside a paper →
radiology-grant. - Full-project state, provenance, and cross-artifact consistency →
radiology-pipeline.
Related Skills
taste-skill
116.8kAgent skills that give coding agents taste: art direction, reference images and a browser check instead of generic AI pages
Agent-Reach
112.3kGive your AI agent eyes to see the entire internet. Read & search Twitter, Reddit, YouTube, GitHub, Bilibili, XiaoHongShu — one CLI, zero API fees.
ruflo
81.9k🌊 The original agent harness. Deploy intelligent multi-player swarms, coordinate autonomous workflows, and build conversational AI systems. Features adaptive memory, self-learning intelligence, federation, vector RAG integration, and native Claude Code / Codex / Hermes and many more Integrated
Claude-Code-Game-Studios
39.7kTurn Claude Code into a full game dev studio — 49 AI agents, 72 workflow skills, and a complete coordination system mirroring real studio hierarchy.
Languages
Trust signals
From repository metadata: license, adoption, age and documentation. Not a code audit — see the Safety scan above for what the skill file itself contains.
