IoTClient
This is an IoT device communication protocol implementation client, which will include common industrial communication protocols such as mainstream PLC communication reading, ModBus protocol, and Bacnet protocol. This component is open source and free for life, using the most relaxed MIT open source agreement, you can modify and commercial use at will (commercial use please evaluate and test). 这是一个物联网设备通讯协议实现客户端,将会包括主流PLC通信读取、ModBus协议、Bacnet协议等常用工业通讯协议。本组件终身开源免费,采用最宽松的MIT开源协议,您可以随意修改和商业使用(商业使用请做好评估和测试)。
Install / Use
/learn @zhaopeiym/IoTClientREADME
English | 中文文档
- This is an IoT device communication protocol realization client, which will include mainstream PLC communication reading, ModBus protocol, Bacnet protocol and other common industrial communication protocols.
- This component is based on .NET Standard 2.0 and can be used for cross-platform development of .Net, such as Windows, Linux and even run on Raspberry Pi.
- This component is open source and free for life, and adopts the most relaxed MIT protocol. You can also modify and use it for commercial use (commercial use please evaluate and test).
- Development tools:Visual Studio 2019
- QQ exchange group:700324594
Document directory
<!-- TOC -->- Instructions for use
- Reference component
- ModBusTcp read and write operations
- ModBusRtu read and write operations
- ModBusAscii read and write operations
- ModbusRtuOverTcp read and write operations
- SiemensClient (Siemens) read and write operations
- Note: About Siemens PLC address
- SiemensClient best practices
- MitsubishiClient (Mitsubishi) read and write operations
- OmronFinsClient (Omron) read and write operations
- AllenBradleyClient read and write operations
- Some projects based on IoTClient library
Instructions for use
Reference component
Nuget installation Install-Package IoTClient
Or graphical installation

ModBusTcp read and write operations
//1、Instantiate the client-enter the correct IP and port
ModBusTcpClient client = new ModBusTcpClient("127.0.0.1", 502);
//2、Write operation-parameters are: address, value, station number, function code
client.Write("4", (short)33, 2, 16);
//2.1、[Note] When writing data, you need to clarify the data type
client.Write("0", (short)33, 2, 16); //Write short type value
client.Write("4", (ushort)33, 2, 16); //Write ushort type value
client.Write("8", (int)33, 2, 16); //Write int type value
client.Write("12", (uint)33, 2, 16); //Write uint type value
client.Write("16", (long)33, 2, 16); //Write long type value
client.Write("20", (ulong)33, 2, 16); //Write ulong type value
client.Write("24", (float)33, 2, 16); //Write float type value
client.Write("28", (double)33, 2, 16); //Write double type value
client.Write("32", true, 2, 5); //Write Coil type value
client.Write("100", "orderCode", stationNumber); //Write string
//3、Read operation-the parameters are: address, station number, function code
var value = client.ReadInt16("4", 2, 3).Value;
//3.1、Other types of data reading
client.ReadInt16("0", stationNumber, 3); //short type data read
client.ReadUInt16("4", stationNumber, 3); //ushort type data read
client.ReadInt32("8", stationNumber, 3); //int type data read
client.ReadUInt32("12", stationNumber, 3); //uint type data read
client.ReadInt64("16", stationNumber, 3); //long type data read
client.ReadUInt64("20", stationNumber, 3); //ulong type data read
client.ReadFloat("24", stationNumber, 3); //float type data read
client.ReadDouble("28", stationNumber, 3); //double type data read
client.ReadCoil("32", stationNumber, 1); //Coil type data read
client.ReadDiscrete("32", stationNumber, 2);//Discrete type data read
client.ReadString("100", stationNumber,readLength:10); //Read string
//4、If there is no active Open, it will automatically open and close the connection every time you read and write operations, which will greatly reduce the efficiency of reading and writing. So it is recommended to open and close manually.
client.Open();
//5、Read and write operations will return the operation result object Result
var result = client.ReadInt16("4", 2, 3);
//5.1 Whether the reading is successful (true or false)
var isSucceed = result.IsSucceed;
//5.2 Exception information for failed reading
var errMsg = result.Err;
//5.3 Read the request message actually sent by the operation
var requst = result.Requst;
//5.4 Read the response message from the server
var response = result.Response;
//5.5 Read value
var value3 = result.Value;
//6、Batch read
var list = new List<ModBusInput>();
list.Add(new ModBusInput()
{
Address = "2",
DataType = DataTypeEnum.Int16,
FunctionCode = 3,
StationNumber = 1
});
list.Add(new ModBusInput()
{
Address = "2",
DataType = DataTypeEnum.Int16,
FunctionCode = 4,
StationNumber = 1
});
list.Add(new ModBusInput()
{
Address = "199",
DataType = DataTypeEnum.Int16,
FunctionCode = 3,
StationNumber = 1
});
var result = client.BatchRead(list);
//7、Other parameters of the constructor
//IP, port, timeout time, big and small end settings
ModBusTcpClient client = new ModBusTcpClient("127.0.0.1", 502, 1500, EndianFormat.ABCD);
For more usage of ModBusTcp, please refer to Unit Test
ModBusRtu read and write operations
//Instantiate the client-[COM port name, baud rate, data bits, stop bits, parity]
ModBusRtuClient client = new ModBusRtuClient("COM3", 9600, 8, StopBits.One, Parity.None);
//Other read and write operations are the same as ModBusTcpClient's read and write operations
ModBusAscii read and write operations
//Instantiate the client-[COM port name, baud rate, data bits, stop bits, parity]
ModbusAsciiClient client = new ModbusAsciiClient("COM3", 9600, 8, StopBits.One, Parity.None);
//Other read and write operations are the same as ModBusTcpClient's read and write operations
ModbusRtuOverTcp read and write operations
//Serial port transparent transmission i.e.: send Rtu format messages in Tcp mode
//Instantiate the client-IP, port, timeout, big and small end settings
ModbusRtuOverTcpClient client = new ModbusRtuOverTcpClient("127.0.0.1", 502, 1500, EndianFormat.ABCD);
//Other read and write operations are the same as ModBusTcpClient's read and write operations
SiemensClient (Siemens) read and write operations
//1、Instantiate the client-enter the model, IP and port
//Other models:SiemensVersion.S7_200、SiemensVersion.S7_300、SiemensVersion.S7_400、SiemensVersion.S7_1200、SiemensVersion.S7_1500
SiemensClient client = new SiemensClient(SiemensVersion.S7_200Smart, "127.0.0.1",102);
//2、Write operation
client.Write("Q1.3", true);
client.Write("V2205", (short)11);
client.Write("V2209", 33);
//3、Read operation
var value1 = client.ReadBoolean("Q1.3").Value;
var value2 = client.ReadInt16("V2205").Value;
var value3 = client.ReadInt32("V2209").Value;
//4、If there is no active Open, it will automatically open and close the connection every time you read and write operations, which will greatly reduce the efficiency of reading and writing. So it is recommended to open and close manually.
client.Open();
//5、Read and write operations will return the operation result object Result
var result = client.ReadInt16("V2205");
//5.1 Whether the reading is successful (true or false)
var isSucceed = result.IsSucceed;
//5.2 Exception information for failed reading
var errMsg = result.Err;
//5.3 Read the request message actually sent by the operation
var requst = result.Requst;
//5.4 Read the response message from the server
var response = result.Response;
//5.5 Read value
var value4 = result.Value;
Note: About Siemens PLC address
VB263、VW263、VD263中的B、W、D分别表示:byte型(8位)、word型(16位)、doubleword型(32位)。
When this component passes in the address, there is no need to carry the data type, just use the corresponding method to read the corresponding type, such as:
VB263 - client.ReadByte("V263")
VD263 - client.ReadFloat("V263")
VD263 - client.ReadInt32("V263")
DB108.DBW4 - client.ReadUInt16("DB108.4")
DB1.DBX0.0 - client.ReadBoolean("DB1.0.0")
DB1.DBD0 - client.ReadFloat("DB1.0")
|C# data type | smart200 | 1200/1500/300 |---|---|--- |bit | V1.0 | DB1.DBX1.0 |byte | VB1 | DB1.DBB1 |shor <br> ushort | VW2 | DB1.DBW2 |int <br> uint <br> float | VD4 | DB1.DBD4
SiemensClient best practices
1、When not to take the initiative to open
Siemens plc generally allows up to 8 long connections. So when t