SkillAgentSearch skills...

specifying-plant-models

Specify plant models for closed-loop simulation: system specs, architecture, build plans, validation plans

Install / Use

npx skills add matlab/simulink-agentic-toolkit --skill specifying-plant-models

Installs into whichever agent you are using.

About this skill
📄

SKILL.md

Installable skill definition

Quality Score

87/100

Supported Platforms

Universal

Our assessment of specifying-plant-models

specifying-plant-models scores 87/100 on our quality scale, 2091st of 4,644 Development & Engineering skills we index (top 46%).

Its SKILL.md is 8.5 KB long, well organised into 18 sections with 2 code examples: a thorough specification that gives an agent plenty to work with.

With 1,148 GitHub stars, it is one of the more widely adopted skills in the catalogue.

Substance
29/30
Structure
18/20
Description
12/15
Adoption
13/20
Freshness
15/15

Maintenance, license and trust

  • The repository was last updated 18 days ago, so specifying-plant-models is actively maintained.
  • No license is declared. By default that means all rights are reserved: you can read it, but reusing or redistributing it is not clearly permitted. Ask the author before building on it commercially.
  • Its trust signals score 88/100, with 1 caution from licensing, adoption, age or documentation. These come from repository metadata, not a code audit — read the skill file before letting an agent act on it.

specifying-plant-models compared with similar skills

All 4 of these similar skills score higher than specifying-plant-models; compare them before choosing.

SkillScoreStarsUpdatedFormat
specifying-plant-models (this skill)by matlab871.1k18d agoSKILL.md
ai-job-searchby MadsLorentzen10045.0k1d agoCLAUDE.md
claude-howtoby luongnv8910041.7k5d agoCLAUDE.md
algorithmic-artby anthropics100177.9k12d agoSKILL.md
pptxby anthropics100177.9k12d agoSKILL.md

Frequently asked questions

How do I install specifying-plant-models?
Run npx skills add matlab/simulink-agentic-toolkit --skill specifying-plant-models. The install tabs above show the steps for each supported agent.
Which AI agents does specifying-plant-models work with?
It is written for Universal, as a SKILL.md file. Other agents that read the same format can often use it too.
Is specifying-plant-models safe to use?
It declares no license and scores 88/100 on trust signals. Skills are instructions an agent will follow, so read the file before installing it and do not approve commands you do not understand.
Is specifying-plant-models still maintained?
The repository was last updated 18 days ago, so specifying-plant-models is actively maintained.

name: specifying-plant-models description: "Specify plant models for closed-loop simulation: system specs, architecture, build plans, validation plans. Use when creating, updating, or reviewing plant model specifications, planning plant model architecture, or planning plant model validation." license: https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md metadata: author: MathWorks version: "1.1"

Plant Model Specs

Structured specification of plant models for closed-loop simulation. Adapts the specifying-software templates for the physics-modeling domain.

When to Use

  • Creating a plant model to close the loop with an existing controller
  • Updating or extending an existing plant model spec
  • Specifying a plant model before building it
  • Deciding on model architecture (subsystem decomposition, fidelity level)
  • Planning validation of a plant model

When NOT to Use

  • Building the plant model → use building-simulink-models
  • Testing an existing plant model → use testing-simulink-models
  • Specs for controller algorithms or MBD algorithms → use specifying-mbd-algorithms
  • Specs for traditional software (C, C++, Python, MATLAB scripts) → use specifying-software
  • Specifying a full closed-loop system → use specifying-mbd-algorithms for the algorithm side, this skill for the plant side

Output Conventions

Store specs per plant model. Prefix every filename with the plant name so files are self-identifying in editor tabs, search results, and flat listings:

docs/specs/plant-models/<plant-name>/
├── <plant-name>-system.md              # What & why
├── <plant-name>-architecture.md        # Subsystem decomposition
├── <plant-name>-implementation-plan.md # Build sequence
└── <plant-name>-test-plan.md           # Validation plan

Example for a plant called motor:

docs/specs/plant-models/motor/
├── motor-system.md
├── motor-architecture.md
├── motor-implementation-plan.md
└── motor-test-plan.md

Mode Selection

Does this plant have <5 states, single-rate dynamics, no strong nonlinearities, and will be built by one person/agent?

  • Yes → Quick spec: 2 documents (system+architecture combined, implementation+test combined)
  • No → Full spec: 4 separate documents

Document Boundaries

| Spec | Answers | Does NOT Contain | |------|---------|------------------| | System | What are we building and why? | Subsystem decomposition, equations | | Architecture | How is it structured? | Simulink block details, parameter values | | Implementation Plan | How do we build it? | Actual model_edit commands | | Test Plan | How do we validate it? | Test execution results |

In quick mode, combine system+architecture and implementation+test into two documents.

Workflow

Step 1: Analyze Controller Interface

Read the controller model with model_overview and model_read. Classify every signal as:

  • u (commanded inputs from controller), w (exogenous disturbances),
  • y (measured outputs to controller, with sensor effects), z (truth outputs for debugging)

Define the plant boundary and document sample times.

Step 2: Assess Validation Evidence

Before researching the domain, establish what evidence exists: test data, datasheets, standard maneuvers, analytic expectations, reference models.

Fidelity must be justified by available evidence — no point modeling dynamics you can't validate. Intended use matters: MIL rapid iteration → lower fidelity acceptable; HIL/code generation → fixed-step, real-time constraints.

Step 3: Research the Physics Domain

Use web_search and read_web_page for standard modeling approaches, reference parameters, and authoritative sources. Consult references/plant-model-guidance.md for cross-domain patterns if needed.

Step 4: Write System Spec

Use assets/system-spec-template.md. Key plant-model sections: operating scenarios, physical model requirements, controller interface contract (u/w/y/z with sample times, data types, units), initialization & operating points, rate & timing alignment, validation evidence, reference sources.

Review gate before proceeding — verify:

  • Completeness of interface requirements (u, y signals covered)
  • Appropriate fidelity given intended use AND available validation evidence
  • Coverage of controller's operating envelope in operating scenarios
  • Operating points / initialization strategy specified and feasible
  • Rate/sample time alignment with controller defined
  • Clear validation reference for each major requirement

Get user review before proceeding.

Step 5: Write Architecture Spec

Use assets/architecture-spec-template.md. Key plant-model sections: component catalog with physics domain and port interfaces, equations of motion per subsystem, nonlinearities & constraints, numerical considerations (solver, stiffness, algebraic loops), parameter management, uncertainty hooks.

Review gate before finalizing — verify:

  • Correct physics decomposition — subsystem boundaries at natural domain boundaries
  • Complete signal flow from u through dynamics to y
  • Disturbances w entering at the right points
  • Consistent interfaces: units, sign conventions, coordinate frames end-to-end
  • DAE / algebraic loop risks addressed; conservation laws respected
  • Missing dynamics that affect the controller (actuator limits, sensor noise, transport delays)

Get user review before proceeding.

Step 6: Write Implementation Plan + Test Plan

Use assets/implementation-plan-template.md and assets/test-plan-template.md.

Implementation plan essentials:

  • Phase 0 (interface contract & stubs) gates all parallel work — freeze ports/units/sign conventions first
  • Loosely coupled subsystems (sensors, actuators, load, environment) can be built by separate agents concurrently after Phase 0; tightly coupled splits (inverter↔motor, tire↔chassis) need coordination
  • Model References enable the strongest parallel development (separate .slx files)
  • Parameter table: every parameter with name, value, unit, source, block path
  • Sync points use model_read verification and model_query_params spot-checks

Test plan essentials:

  • Three-stage validation: subsystem open-loop → integrated open-loop → closed-loop
  • Input signal definitions with parameters (step, ramp, sine sweep)
  • Gherkin scenarios mapped to model_test format
  • Quantitative acceptance criteria with physical justification

Review gate — Implementation Plan — verify:

  • Realistic bottom-up build order (leaf subsystems first)
  • Phase 0 interface stubs gate parallel work
  • Correct Simulink block types for the physics
  • Solver choice matches stiffness + discrete elements
  • Complete parameter table with sources and units

Review gate — Test Plan — verify:

  • Validation staging: subsystem open-loop → integrated open-loop → closed-loop (MIL)
  • Real-time execution feasibility assessed if plant is HIL-targeted
  • Each maneuver specifies: input, outputs, comparison method, acceptance criteria
  • Parameter sensitivity checks included
  • Numerical robustness test (solver tolerance, step size)
  • Gherkin scenarios executable via model_test

Get user approval before building begins.

Guardrails

Always

  • Classify signals as u/w/y/z at every interface
  • Cite sources for every parameter (value, unit, source, uncertainty, conditions)
  • Assess validation evidence before choosing fidelity level
  • Decompose into subsystems at natural domain boundaries (actuator, dynamics, sensor, environment, load)

Ask First

  • Fidelity level changes after system spec is approved
  • Adding subsystems not in the architecture spec
  • Deviating from the controller's sample time alignment

Never

  • Reproduce textbook derivations in specs — cite authoritative sources instead; use web_search for domain-specific research
  • Model dynamics you cannot validate against available evidence
  • Skip Phase 0 interface stubs when parallel building is planned
  • Use web_search results from unvetted sources — prefer standards, textbooks, MathWorks docs, and peer-reviewed papers

References

  • assets/system-spec-template.md — System spec template (what & why)
  • assets/architecture-spec-template.md — Architecture template (subsystem decomposition)
  • assets/implementation-plan-template.md — Build sequence template
  • assets/test-plan-template.md — Validation plan template
  • references/plant-model-guidance.md — Optional domain reference (decomposition examples, validation maneuvers, solver guide). Human-facing; do not copy verbatim into specs.

Copyright 2026 The MathWorks, Inc.


Related Skills

View on GitHub
GitHub Stars1.1k
CategoryDevelopment
Updated18d ago
Forks106

Languages

HTML

Trust signals

88/100

From repository metadata: license, adoption, age and documentation. Not a code audit — see the Safety scan above for what the skill file itself contains.

1 medium