SkillAgentSearch skills...

create-sdi-run

Import data into the Simulation Data Inspector (SDI) from MAT, CSV, or Excel files, from workspace variables, or from a Simulink simulation

Install / Use

npx skills add matlab/simulink-agentic-toolkit --skill create-sdi-run

Installs into whichever agent you are using.

About this skill
📄

SKILL.md

Installable skill definition

Quality Score

93/100

Supported Platforms

Universal

Tags

Our assessment of create-sdi-run

create-sdi-run scores 93/100 on our quality scale, 132nd of 505 Data & Analytics skills we index (top 27%).

Its SKILL.md is 15 KB long, well organised into 18 sections with 13 code examples: a thorough specification that gives an agent plenty to work with.

With 1,148 GitHub stars, it is one of the more widely adopted skills in the catalogue.

Substance
30/30
Structure
20/20
Description
15/15
Adoption
13/20
Freshness
15/15

Maintenance, license and trust

  • The repository was last updated 16 days ago, so create-sdi-run is actively maintained.
  • No license is declared. By default that means all rights are reserved: you can read it, but reusing or redistributing it is not clearly permitted. Ask the author before building on it commercially.
  • Its trust signals score 88/100, with 1 caution from licensing, adoption, age or documentation. These come from repository metadata, not a code audit — read the skill file before letting an agent act on it.

create-sdi-run compared with similar skills

All 4 of these similar skills score higher than create-sdi-run; compare them before choosing.

SkillScoreStarsUpdatedFormat
create-sdi-run (this skill)by matlab931.1k16d agoSKILL.md
algorithmic-artby anthropics100177.9k11d agoSKILL.md
pptxby anthropics100177.9k11d agoSKILL.md
designby nextlevelbuilder100130.2k12d agoSKILL.md
ui-ux-pro-maxby nextlevelbuilder100130.2k12d agoSKILL.md

Frequently asked questions

How do I install create-sdi-run?
Run npx skills add matlab/simulink-agentic-toolkit --skill create-sdi-run. The install tabs above show the steps for each supported agent.
Which AI agents does create-sdi-run work with?
It is written for Universal, as a SKILL.md file. Other agents that read the same format can often use it too.
Is create-sdi-run safe to use?
It declares no license and scores 88/100 on trust signals. Skills are instructions an agent will follow, so read the file before installing it and do not approve commands you do not understand.
Is create-sdi-run still maintained?
The repository was last updated 16 days ago, so create-sdi-run is actively maintained.

name: create-sdi-run description: > Import data into the Simulation Data Inspector (SDI) from MAT, CSV, or Excel files, from workspace variables, or from a Simulink simulation. Use when the user wants to view a logged file in SDI, load a bench-test log, or verify what a just-completed Simulink.sdi.createRun or sim(model) produced. Covers the 'file', 'vars', and 'namevalue' sources of createRun, the auto-populate behavior after sim(), and post-import verification. Not for comparing existing runs (use Simulink.sdi.compareRuns); not for streaming data live during a running simulation (use Simulink.sdi.createRunOrAddToStreamedRun — a separate API); and not for authoring Gherkin or Simulink Test test cases, assertions, or regression tests (use testing-simulink-models). Do not activate on test-authoring or verification prompts even when no test-authoring skill is available — say so and stop. license: https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md metadata: author: MathWorks version: "1.0"

Create SDI Run

Get data into the Simulation Data Inspector using the shortest path that works. Most agents reflexively read files into the workspace and rebuild signals by hand; this skill teaches the direct paths and when each applies.

When to Use

  • User has a .mat, .csv, or .xlsx file of logged data and wants to view it in SDI.
  • User just ran sim(model) and wants to see the logged signals.
  • User has timeseries, timetable, or Simulink.SimulationData.Dataset variables in the workspace and wants an SDI run.
  • User asks about Simulink.sdi.createRun, Simulink.sdi.getAllRunIDs, or Simulink.sdi.getRun.

When NOT to Use

  • Comparing two existing runs — that is a distinct workflow (Simulink.sdi.compareRuns).
  • Streaming data live during a running simulation — this is a separate API (Simulink.sdi.createRunOrAddToStreamedRun), not a mode of createRun. Prompts like "stream data into SDI while my sim is running" belong to that API. Do not activate on those.
  • Files in MDF (.mf4), ULG, ROS bag, CAN log, or HDF5 formats — see references/format-support.md for what SDI reads natively vs. what needs a different toolbox.
  • Customizing plot layout, cursors, or subplot arrangement beyond opening the SDI window.
  • Authoring Gherkin .feature files, Simulink Test cases, matlab.unittest classes, or any pass/fail assertions or regression tests for a model or subsystem — use testing-simulink-models (Gherkin-based model_test, requires Simulink Test). Prompts like "write a Gherkin test for X", "verify abs(-5) equals 5", "create a regression test for this subsystem", or any request whose deliverable is a test artifact belong there. Do not activate this skill on such prompts even when testing-simulink-models is unavailable — in that case, tell the user which skill is missing and stop.

Workflow

Answer these four questions in order. The first "yes" tells you what to do.

1. Is the data already in SDI?

After sim(model) with signal logging enabled, SDI auto-populates one run. Do not call createRun — that produces a duplicate.

before = Simulink.sdi.getAllRunIDs;
simOut = sim("myModel");
after  = Simulink.sdi.getAllRunIDs;
if numel(after) > numel(before)
    Simulink.sdi.view;   % done — just open the window
end

If no new run appeared, logging is off. Enable it via the Simulink Agentic Toolkit model_edit tool with a configure op setting DataLogging on the target port, then re-simulate — or fall back to Step 3 with simOut. As a last resort, ask the user to right-click a signal → Log Selected Signals in the Simulink editor themselves; that step is for the user to perform, not the agent.

2. Is the data in a file?

Use the 'file' source. One call handles MAT, CSV, and Excel natively — no load, no readtable, no sheetnames loop.

runID = Simulink.sdi.createRun("bench_test","file","logs/bench_test.mat");

Excel with N sheets returns a 1×N int32 vector — one run ID per sheet. All returned runs inherit the base name; if the user needs sheet-named runs, rename each run in place with sheetnames() — do not delete and re-import per sheet:

runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx");   % [id1, id2, ...]
sheets = sheetnames("cases.xlsx");
for k = 1:numel(runIDs)
    Simulink.sdi.getRun(runIDs(k)).Name = sheets(k);
end

Time-column header rule (CSV and Excel). SDI's built-in reader requires the time column to be named literally time (case-insensitive). Headers like time_s, t, Time (s), Timestamp cause SDI:sdi:ImportError. Try 'file' first and catch the error — do not pre-inspect the header row and guess, because SDI's matching rules can differ from your interpretation. On SDI:sdi:ImportError, fall back to the readmatrix + array2timetable + 'vars' pattern (Step 3 / CSV pattern below). Do not rewrite the source file.

Other createRun failures. createRun can also throw for reasons this skill does not enumerate — corrupted files, unsupported data types inside a MAT/Excel, malformed structs, permission errors, unregistered custom readers. When you catch an error identifier that is not SDI:sdi:ImportError, do not invent a fix or silently retry. Surface the full error identifier and message to the user, list the file or variables involved, and suggest they inspect the source (e.g., whos("-file",path) for a MAT, or sheetnames(path) plus a per-sheet read for an Excel). Ask before attempting an alternative import path.

3. Is the data in workspace variables?

Two sources, different purposes:

  • 'vars' — pass variables whose names or .Name properties are already correct. This is the default.
  • 'namevalue' — pass explicit signal names when the variables have no .Name metadata (e.g., bare arrays or unnamed timeseries).

Timeseries whose .Name is already what you want:

% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", speedTS, torqueTS);

Timetable — signals inherit the column names:

% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","vars", benchTT);

Bare arrays needing explicit names:

% TEMPLATE — not executable
runID = Simulink.sdi.createRun("baseline","namevalue", ...
    {"velocity","load"}, {velocityData, loadData});

Gotcha (Gap E): if a timeseries passed to 'namevalue' has its own .Name set, .Name wins over the caller-supplied name. To force the name you want, either set ts.Name first and use 'vars', or clear it before 'namevalue'.

4. Verify the run

After every createRun or auto-populate:

ids = Simulink.sdi.getAllRunIDs;
run = Simulink.sdi.getRun(ids(end));
fprintf("Run %d: %s (%d signals)\n", ids(end), run.Name, run.SignalCount);
for k = 1:run.SignalCount
    fprintf("  %s\n", run.getSignalByIndex(k).Name);
end
Simulink.sdi.view;

Verify against MATLAB via the MATLAB MCP server's evaluate_matlab_code tool. If SignalCount == 0, the import silently produced nothing — investigate the source, do not report success.

Key Functions

All available from R2023a with base Simulink; no additional toolbox required.

| Function | Purpose | Available From | |---|---|---| | Simulink.sdi.createRun(name) | Empty run — used with Run.add for a per-signal build; rarely the right first choice. | R2011b | | Simulink.sdi.createRun(name,"file",path) | Import a .mat, .csv, or .xlsx file. Returns scalar int32 for MAT/CSV, 1×N int32 vector for N-sheet Excel. | R2011b | | Simulink.sdi.createRun(name,"vars",v1,v2,...) | Import workspace variables whose names/.Name are correct. | R2011b | | Simulink.sdi.createRun(name,"namevalue",names,values) | Import with explicit names. See Gap E caveat. | R2011b | | Simulink.sdi.view | Open the SDI window. Safe to call repeatedly; opens only if not visible. | R2011b | | Simulink.sdi.getAllRunIDs | Return int32 vector of every run's ID. Use before/after sim to detect auto-populate. | R2017a | | Simulink.sdi.getRun(runID) | Return the Simulink.sdi.Run object for a run ID. | R2011b | | Simulink.sdi.clear | Delete all SDI runs. Ask the user first — destructive. | R2011b |

Four createRun sources exist: empty, 'vars', 'namevalue', 'file'. When unsure, run help Simulink.sdi.createRun.

Patterns

Pattern: MAT file → SDI (one line)

runID = Simulink.sdi.createRun("sensor_log","file","data/sensor_log.mat");
Simulink.sdi.view;

The variables inside the MAT file may be timeseries, timetable, Simulink.SimulationData.Dataset, or legacy struct-with-time — SDI's reader picks them up automatically.

Pattern: CSV file → SDI (try 'file', catch, fall back)

Attempt the one-liner first. On SDI:sdi:ImportError, fall back to the timetable path — do not rewrite the file:

try
    runID = Simulink.sdi.createRun("bench_run","file","logs/bench_run.csv");
catch ME
    if strcmp(ME.identifier,"SDI:sdi:ImportError")
        raw     = readmatrix("logs/bench_run.csv");
        headers = string(readcell("logs/bench_run.csv","Range","1:1"));
        tt = array2timetable(raw(:,2:end), ...
                "RowTimes", seconds(raw(:,1)), ...
                "VariableNames", headers(2:end));
        runID = Simulink.sdi.createRun("bench_run","vars", tt);
    else
        rethrow(ME);
    end
end

Assumes the time column is column 1 and expressed in seconds — the common case for bench logs. If the time column sits elsewhere or uses different units, adjust the index or wrap it with the appropriate duration constructor (milliseconds, minutes, …) before passing to RowTimes.

Pattern: Excel with multiple sheets → one run per sheet

One createRun call per file. Every returned run initially inherits the base name you supplied — SDI does not auto-apply sheet names. Rename in place with sheetnames(); do not delete and re-import per sheet. The same time-column-header rule applies as for CSV — if a sheet's time column is not named time, createRun throws SDI:sdi:ImportError; wrap this call in the same try-then-fallback shown in the CSV pattern, using readmatrix(...,"Sheet",sheets(k)) and readcell(...,"Sheet",sheets(k),"Range","1:1") per sheet.

runIDs = Simulink.sdi.createRun("test_matrix","file","data/two_runs.xlsx");
% runIDs is a 1xN int32 vector — one ID per sheet, all named "test_matrix".
sheets = sheetnames("data/two_runs.xlsx");
for k = 1:numel(runIDs)
    run = Simulink.sdi.getRun(runIDs(k));
    run.Name = sheets(k);   % rename in place to the sheet name
    fprintf("Sheet run: %s (%d signals)\n", run.Name, run.SignalCount);
end

To restrict to specific sheets, use the sheets name-value — the returned vector is trimmed accordingly:

runIDs = Simulink.sdi.createRun("cases","file","cases.xlsx", ...
    sheets=["baseline","variant"]);

Pattern: Post-sim — just open SDI

before = Simulink.sdi.getAllRunIDs;
simOut = sim("controller_test");
after  = Simulink.sdi.getAllRunIDs;

if numel(after) > numel(before)
    Simulink.sdi.view;             % logged signals already imported
else
    % No auto-populate — logging is off. Enable it and re-simulate, or
    % pass simOut through createRun as a fallback:
    Simulink.sdi.createRun("run_from_simout","vars", simOut);
    Simulink.sdi.view;
end

Pattern: Rename workspace signals

Set .Name before 'vars'. This avoids the 'namevalue' override trap.

data = load("data/speed_torque.mat");
speed  = data.speed;
torque = data.torque;
speed.Name  = "velocity";
torque.Name = "torqueNm";
runID = Simulink.sdi.createRun("baseline","vars", speed, torque);

Conventions

Always

  • **Check whether SDI already has the

Truncated for display — read the full file on GitHub.

Related Skills

View on GitHub
GitHub Stars1.1k
CategoryData
Updated16d ago
Forks106

Languages

HTML

Trust signals

88/100

From repository metadata: license, adoption, age and documentation. Not a code audit — see the Safety scan above for what the skill file itself contains.

1 medium