Modsim
A Simple Modbus TCP Device Simulator
Install / Use
/learn @gavinying/ModsimREADME
ModSim - A Simple Modbus TCP Device Simulator
modsim is a simple Modbus TCP device simulator deployed at modsim.topmaker.net:502.
It works as a remote Modbus-TCP (virtual) device, which has already been populated with all 4 types of registers, i.e.
- Coil Type
- Discrete input Type
- Input register Type
- Holding register Type
It is recommended to use modpoll tool to communicate with it, the example configuration is as following,
device,modsim01,1,,
poll,coil,0,16,BE_BE
ref,coil01-08,0,bool8,rw
ref,coil09-16,1,bool8,rw
poll,discrete_input,10000,16,BE_BE
ref,di01-08,10000,bool8,rw
ref,di09-16,10001,bool8,rw
poll,input_register,30000,20,BE_BE
ref,input_reg01,30000,uint16,rw
ref,input_reg02,30001,uint16,rw
ref,input_reg03,30002,uint16,rw
ref,input_reg04,30003,uint16,rw
ref,input_reg05,30004,int16,rw
ref,input_reg06,30005,int16,rw
ref,input_reg07,30006,int16,rw
ref,input_reg08,30007,int16,rw
ref,input_reg09,30008,uint32,rw
ref,input_reg10,30010,uint32,rw
ref,input_reg11,30012,int32,rw
ref,input_reg12,30014,int32,rw
ref,input_reg13,30016,float32,rw
ref,input_reg14,30018,float32,rw
poll,holding_register,40000,44,BE_BE
ref,holding_reg01,40000,uint16,rw
ref,holding_reg02,40001,uint16,rw
ref,holding_reg03,40002,uint16,rw
ref,holding_reg04,40003,uint16,rw
ref,holding_reg05,40004,int16,rw
ref,holding_reg06,40005,int16,rw
ref,holding_reg07,40006,int16,rw
ref,holding_reg08,40007,int16,rw
ref,holding_reg09,40008,uint32,rw
ref,holding_reg10,40010,uint32,rw
ref,holding_reg11,40012,int32,rw
ref,holding_reg12,40014,int32,rw
ref,holding_reg13,40016,float32,rw
ref,holding_reg14,40018,float32,rw
ref,holding_reg15,40020,uint64,rw
ref,holding_reg16,40024,int64,rw
ref,holding_reg17,40028,float64,rw
ref,holding_reg18,40032,float64,rw
ref,holding_reg19,40036,string16,rw
Quick Start
A docker image has been provided for user to directly run the program,
docker run -p 5020:5020 topmaker/modsim:latest
The above one-line command will create a virtual Modbus TCP device running at localhost:5020.
To verify it, you can test by modpoll tool with the following command,
modpoll \
--tcp localhost \
--tcp-port 5020 \
--config https://raw.githubusercontent.com/gavinying/modpoll/main/examples/modsim.csv
Note: add
sudobeforedocker runcommand if you want to use the Modbus TCP standard port502.
Related Skills
node-connect
343.3kDiagnose OpenClaw node connection and pairing failures for Android, iOS, and macOS companion apps
frontend-design
92.1kCreate distinctive, production-grade frontend interfaces with high design quality. Use this skill when the user asks to build web components, pages, or applications. Generates creative, polished code that avoids generic AI aesthetics.
openai-whisper-api
343.3kTranscribe audio via OpenAI Audio Transcriptions API (Whisper).
qqbot-media
343.3kQQBot 富媒体收发能力。使用 <qqmedia> 标签,系统根据文件扩展名自动识别类型(图片/语音/视频/文件)。