SkillAgentSearch skills...

bio-flow-cytometry-doublet-detection

Detect and remove doublets from flow and mass cytometry data. Covers FSC/SSC gating and computational doublet detection methods

Install / Use

npx skills add FreedomIntelligence/OpenClaw-Medical-Skills --skill bio-flow-cytometry-doublet-detection

Installs into whichever agent you are using.

About this skill
📄

SKILL.md

Installable skill definition

Quality Score

89/100

Supported Platforms

Universal

Tags

Our assessment of bio-flow-cytometry-doublet-detection

bio-flow-cytometry-doublet-detection scores 89/100 on our quality scale, 1589th of 4,698 Development & Engineering skills we index (top 34%).

Its SKILL.md is 7.7 KB long, well organised into 56 sections with 10 code examples: a thorough specification that gives an agent plenty to work with.

With 3,034 GitHub stars, it is one of the more widely adopted skills in the catalogue.

Substance
29/30
Structure
20/20
Description
15/15
Adoption
15/20
Freshness
11/15

Maintenance, license and trust

  • The repository was last updated about 4 months ago. That is recent enough to be usable, but agent tooling moves fast, so check the instructions against your agent's current version.
  • Our last check on 2026-10-31 found the source still online.
  • No license is declared. By default that means all rights are reserved: you can read it, but reusing or redistributing it is not clearly permitted. Ask the author before building on it commercially.
  • Its trust signals score 86/100, with 1 caution from licensing, adoption, age or documentation. These come from repository metadata, not a code audit — read the skill file before letting an agent act on it.

Safety scan

No issues found

Our scan of the whole file found no instruction hijacking, hidden characters, credential access, data exfiltration or destructive commands. An AI review of the same text found nothing harmful.

AI review by kimi-k2.7-code on 2026-09-29. Automated pattern scan on 2026-09-29. It catches known dangerous patterns, not every risk — read a skill before letting an agent act on it.

bio-flow-cytometry-doublet-detection compared with similar skills

All 4 of these similar skills score higher than bio-flow-cytometry-doublet-detection; compare them before choosing.

SkillScoreStarsUpdatedFormat
bio-flow-cytometry-doublet-detection (this skill)by FreedomIntelligence893.0k4mo agoSKILL.md
taste-skillby Leonxlnx100116.8k8d agoCLAUDE.md
ai-job-searchby ai-job-search-dev10072.1ktodayCLAUDE.md
claude-howtoby luongnv8910047.3k2d agoCLAUDE.md
lobehubby lobehub10085.6ktodayMCP Server

Frequently asked questions

How do I install bio-flow-cytometry-doublet-detection?
Run npx skills add FreedomIntelligence/OpenClaw-Medical-Skills --skill bio-flow-cytometry-doublet-detection. The install tabs above show the steps for each supported agent.
Which AI agents does bio-flow-cytometry-doublet-detection work with?
It is written for Universal, as a SKILL.md file. Other agents that read the same format can often use it too.
Is bio-flow-cytometry-doublet-detection safe to use?
Our scan of the whole file found no instruction hijacking, hidden characters, credential access, data exfiltration or destructive commands. An AI review of the same text found nothing harmful. It declares no license and scores 86/100 on trust signals. Skills are instructions an agent will follow, so read the file before installing it and do not approve commands you do not understand.
Is bio-flow-cytometry-doublet-detection still maintained?
The repository was last updated about 4 months ago. That is recent enough to be usable, but agent tooling moves fast, so check the instructions against your agent's current version.

name: bio-flow-cytometry-doublet-detection description: Detect and remove doublets from flow and mass cytometry data. Covers FSC/SSC gating and computational doublet detection methods. Use when filtering out cell aggregates before clustering or quantitative analysis. tool_type: r primary_tool: flowCore

Version Compatibility

Reference examples tested with: flowCore 2.14+, ggplot2 3.5+

Before using code patterns, verify installed versions match. If versions differ:

  • R: packageVersion('<pkg>') then ?function_name to verify parameters

If code throws ImportError, AttributeError, or TypeError, introspect the installed package and adapt the example to match the actual API rather than retrying.

Doublet Detection

"Remove doublets from my flow cytometry data" → Detect and filter out cell aggregates using FSC-A/FSC-H gating or computational methods before clustering or quantitative analysis.

  • R: flowCore rectangular gates on FSC-A vs FSC-H

FSC-A vs FSC-H Gating (Standard Method)

library(flowCore)
library(ggcyto)

# Load data
fs <- read.flowSet(list.files('data/', pattern = '\\.fcs$', full.names = TRUE))

# FSC-A vs FSC-H for doublet discrimination
# Singlets fall on diagonal, doublets have higher FSC-A for given FSC-H

# Manual rectangular gate
singlet_gate <- rectangleGate(
    filterId = 'singlets',
    'FSC-A' = c(50000, 250000),
    'FSC-H' = c(50000, 250000)
)

# Or use polygon gate for diagonal
singlet_polygon <- polygonGate(
    filterId = 'singlets',
    .gate = data.frame(
        'FSC-A' = c(50000, 250000, 250000, 50000),
        'FSC-H' = c(40000, 200000, 260000, 60000)
    )
)

# Apply gate
singlets <- Subset(fs, singlet_gate)

# Visualize
autoplot(fs[[1]], 'FSC-A', 'FSC-H') + geom_gate(singlet_gate)

Automated Singlet Gating with flowDensity

library(flowDensity)

# Automatic singlet gate
singlet_result <- flowDensity(
    fs[[1]],
    channels = c('FSC-A', 'FSC-H'),
    position = c(TRUE, TRUE),
    gates = c(NA, NA)
)

# Get gated population
singlets <- getflowFrame(singlet_result)

# Percentage singlets
pct_singlets <- nrow(singlets) / nrow(fs[[1]]) * 100
cat('Singlets:', round(pct_singlets, 1), '%\n')

flowAI Quality Control

library(flowAI)

# flowAI performs comprehensive QC including:
# - Flow rate anomaly detection
# - Signal acquisition anomaly detection
# - Dynamic range anomaly detection

# Run flowAI
fs_qc <- flow_auto_qc(
    fs,
    folder_results = 'flowAI_results',
    fcs_QC = TRUE,
    fcs_highQ = TRUE
)

# Results include singlet detection based on flow rate stability

FSC-A/FSC-W Method (Width Parameter)

# Some instruments provide FSC-W (width) instead of FSC-H
# FSC-A = FSC-H × FSC-W
# Doublets have higher width

if ('FSC-W' %in% colnames(fs[[1]])) {
    singlet_gate_w <- rectangleGate(
        filterId = 'singlets',
        'FSC-A' = c(50000, 250000),
        'FSC-W' = c(50000, 100000)  # Lower width = singlets
    )

    singlets <- Subset(fs, singlet_gate_w)
}

Ratio-Based Doublet Detection

# Calculate FSC-A/FSC-H ratio
# Singlets have ratio close to constant (based on pulse geometry)
# Doublets have elevated ratio

calculate_fsc_ratio <- function(ff) {
    fsc_a <- exprs(ff)[, 'FSC-A']
    fsc_h <- exprs(ff)[, 'FSC-H']

    ratio <- fsc_a / (fsc_h + 1)  # Add small value to avoid division by zero
    return(ratio)
}

# Add ratio as derived parameter
for (i in 1:length(fs)) {
    ratio <- calculate_fsc_ratio(fs[[i]])
    fs[[i]] <- cbind2(fs[[i]], ratio)
    colnames(fs[[i]])[ncol(fs[[i]])] <- 'FSC_ratio'
}

# Gate on ratio
ratio_cutoff <- quantile(exprs(fs[[1]])[, 'FSC_ratio'], 0.95)
singlet_gate_ratio <- rectangleGate(filterId = 'singlets', 'FSC_ratio' = c(0, ratio_cutoff))

SSC-Based Doublet Detection

# For cell types where FSC doesn't discriminate well,
# use SSC-A vs SSC-H additionally

ssc_singlet_gate <- rectangleGate(
    filterId = 'ssc_singlets',
    'SSC-A' = c(10000, 200000),
    'SSC-H' = c(10000, 200000)
)

# Combine FSC and SSC gates
combined_gate <- singlet_gate & ssc_singlet_gate
singlets <- Subset(fs, combined_gate)

CyTOF Doublet Detection

library(CATALYST)

# For CyTOF data, use DNA channels or event length

# DNA-based doublet detection (if DNA channels present)
# Doublets have ~2x DNA content
sce <- prepData(fs, panel, md)

# If Event_length channel exists
if ('Event_length' %in% rownames(sce)) {
    event_length <- assay(sce)['Event_length', ]
    singlet_idx <- event_length < quantile(event_length, 0.95)

    sce_singlets <- sce[, singlet_idx]
    cat('Removed', sum(!singlet_idx), 'doublets based on event length\n')
}

# DNA intercalator method
if (all(c('DNA1', 'DNA2') %in% rownames(sce))) {
    dna_total <- assay(sce)['DNA1', ] + assay(sce)['DNA2', ]
    dna_cutoff <- quantile(dna_total, 0.95)

    singlet_idx <- dna_total < dna_cutoff
    sce_singlets <- sce[, singlet_idx]
}

CATALYST Workflow with Doublet Removal

Goal: Detect and remove cell doublets from a CyTOF/flow dataset using a regression-based approach on scatter parameters.

Approach: Model the expected FSC-A vs FSC-H relationship for singlets with linear regression, classify events with large residuals (above the 95th percentile) as doublets, and filter them out.

library(CATALYST)

# Load and prepare data
sce <- prepData(fs, panel, md, transform = TRUE, cofactor = 5)

# Remove doublets using marker-based method
sce <- filterSCE(sce, !is_doublet(sce))

# Custom doublet detection based on FSC
fsc_a <- colData(sce)$FSC_A
fsc_h <- colData(sce)$FSC_H

# Model expected singlet relationship
fit <- lm(fsc_a ~ fsc_h)
residuals <- abs(fsc_a - predict(fit))
threshold <- quantile(residuals, 0.95)

# Mark doublets
colData(sce)$doublet <- residuals > threshold
sce_singlets <- sce[, !colData(sce)$doublet]

cat('Doublet rate:', round(mean(colData(sce)$doublet) * 100, 1), '%\n')

Batch Processing

# Process all samples
detect_doublets <- function(ff, method = 'fsc') {
    if (method == 'fsc') {
        fsc_a <- exprs(ff)[, 'FSC-A']
        fsc_h <- exprs(ff)[, 'FSC-H']

        fit <- lm(fsc_a ~ fsc_h)
        residuals <- abs(fsc_a - predict(fit))
        threshold <- quantile(residuals, 0.95)

        singlet_idx <- residuals <= threshold
    } else if (method == 'ratio') {
        ratio <- exprs(ff)[, 'FSC-A'] / (exprs(ff)[, 'FSC-H'] + 1)
        singlet_idx <- ratio < quantile(ratio, 0.95)
    }

    return(ff[singlet_idx, ])
}

# Apply to all samples
fs_singlets <- fsApply(fs, detect_doublets, method = 'fsc')

# Report
doublet_rates <- sapply(1:length(fs), function(i) {
    1 - nrow(fs_singlets[[i]]) / nrow(fs[[i]])
})
cat('Mean doublet rate:', round(mean(doublet_rates) * 100, 1), '%\n')

Visualization

library(ggplot2)

# Extract data for plotting
plot_data <- data.frame(
    FSC_A = exprs(fs[[1]])[, 'FSC-A'],
    FSC_H = exprs(fs[[1]])[, 'FSC-H']
)

# Calculate doublet status
fit <- lm(FSC_A ~ FSC_H, data = plot_data)
plot_data$residual <- abs(plot_data$FSC_A - predict(fit))
plot_data$doublet <- plot_data$residual > quantile(plot_data$residual, 0.95)

# Plot
ggplot(plot_data, aes(x = FSC_H, y = FSC_A, color = doublet)) +
    geom_point(alpha = 0.3, size = 0.5) +
    scale_color_manual(values = c('gray', 'red')) +
    theme_bw() +
    labs(title = 'Doublet Detection', x = 'FSC-H', y = 'FSC-A')
ggsave('doublet_detection.png', width = 8, height = 6)

Related Skills

Workflow order: cytometry-qc → doublet-detection → bead-normalization → clustering

  • cytometry-qc - Run first: identify flow rate and signal issues
  • bead-normalization - Run after: correct remaining instrument drift
  • fcs-handling - Load FCS files
  • gating-analysis - Manual gating workflows
  • clustering-phenotyping - Downstream analysis after doublet removal

Related Skills

View on GitHub
GitHub Stars3.0k
CategoryDevelopment
Updated3mo ago
Forks413

Languages

Python

Trust signals

86/100

From repository metadata: license, adoption, age and documentation. Not a code audit — see the Safety scan above for what the skill file itself contains.